Page 128 - The Indian Optician Digital Edition May-June 2023
P. 128

TABLE 1 - IPAD BASED CONTRAST STEREOACUITY
                                               OD                       OS                       OU

                     PRE                   1.76 ± 0.90              1.80 ± 0.91               1.91 ± 0.95
                    POST                    1.82 ± 0.91              1.85 ± 0.91              1.99 ± 1.00
                  P-VALUE                     0.17                     0.02                     0.24


          monovision correction, or bifocal and multifocal    subsequent square, the contrast is reduced in
          correction based on alternating or simultaneous     increments of 0.3 log MAR units. The first three
          image principles. The purpose of bifocal and        sequences present the same set of contrasts
          multifocal contact lenses is to bring objects at    again, resulting in two presentations for each
          different distances into sharp focus. Compared      of the 24 contrasts. If the subject does not
          to spectacles, contact lenses are closer to the     respond correctly to two targets in a row, the
          eye, provide a wider field of view, have less       rest of that sequence is skipped, and the next
          distortion, and are more consistent to use since    sequence begins.
          they are not easily removed throughout the
          day. They serve as a platform for bifurcation          The contrast sensitivity is measured in
          and multifocality.                                  log MAR units, and the score expresses the
                                                              reciprocal of the threshold contrast using the
          METHODOLOGY                                         Weber contrast ratio. After providing appropriate
                                                              instructions to the patient, the test is performed,
             This study is prospective and observational,     and the results are recorded upon completion.
          involving 38 subjects aged between 40 and
          60 who met the inclusion criteria and had           IPAD-BASED STEREO ACUITY TEST
          no ocular disease. A detailed ocular and
          systemic history was obtained, followed by a           This test can be performed at multiple
          comprehensive slit lamp examination. Visual         distances, allowing for testing of up to ten
          acuity assessments for distance and near            levels of stereo acuity at each distance. It uses a
          were conducted using Snellen's visual acuity        random dot stereogram viewable with anaglyph
          chart and the N-notation visual acuity chart,       spectacles, and habitual refractive error
          respectively, and were converted to a log MAR       correction is applied. The test has applications
          value. Objective refraction was performed           in visual screening programmes and the design
          using either streak retinoscopy or an auto-         and use of 3D displays are suggested. For depth
          refractometer. Subjective refraction was            perception evaluation, the test is performed at
          also conducted, including a duo chrome test         40 cm with a red filter in front of the right eye
          and binocular balancing, followed by direct         and a green filter in front of the left eye. The
          ophthalmoscopy for fundus evaluation. After         patient must identify the cut portion of a circle
          the primary evaluation, iPad-based stereo acuity    presented on the screen and match it with the
          and contrast sensitivity tests were conducted       side option bar. After each correct answer, the
          using the subject's existing refractive correction.  test proceeds to the next level, and the final
                                                              result is displayed on the screen.
          IPAD-BASED CONTRAST
          SENSITIVITY TEST                                       After the pre-workup and questionnaire with
                                                              existing refractive correction, the patient is
             The blinking square contrast sensitivity test    counselled for a multifocal soft contact lens trial,
          involves showing the patient target squares at      and oral consent is taken. Contact lens fitting
          various contrast levels in different quadrants      measurements, such as keratometry readings,
          of the screen. The patient is then instructed       horizontal visible iris diameter, and pupil
          to touch the quadrant with the target square.       diameter in dim and room illumination, are
          The test is divided into six squares, starting      taken. To fit multifocal soft contacts correctly,
          with a high-contrast square, and with each          identifying the dominant eye is crucial, and an



     124 | THE INDIAN OPTICIAN | MAY-JUNE 2023                                                          OPTOMETRY
   123   124   125   126   127   128   129   130   131   132   133